Summertime temperatures leaving you hot under the collar? In Waterford, WI the vast majority of homes have some sort of system to keep those indoor temperatures down in the summer. At Rosenthal Heating & Air Conditioning we are residential comfort specialists. Installing or replacing central air can be a significant project, so you’ll want to get it right. Our expert air conditioner techs can evaluate you system and your needs and recommend a course of action thats best for you.


Technician cleaned and serviced Rheem A/C unit. Cleaned condenser coil, capacitor, contactor, compressor, controls, wiring, t-stat and unit is working properly at this time.

Waterford, WI
07-24-2018


Rheem A/C tune-up and unit working as designed.

Waterford, WI
07-24-2018

Rheem RAKA-037
Technician cleaned or checked condenser coil, charges, capacitor, contactor, compressor (draining low amps) contols, wiring, stat and filter. Replaced with 3ton Ducane unit.
Waterford, WI
07-24-2018

RAKA-037
Technician cleaned homeowners air ducts.

Waterford, WI
07-24-2018

RAKA-037
Cleaned and services Evcon air conditioning unit. Cooling well at this time.

Waterford, WI
07-25-2018

RAKA-037
Technician performed a routine A/C maintenance on both Lennox units. Cleaned and serviced condenser coils, capacitors, contactors, t-stats, filters. Units operating at this time as designed.

Waterford, WI
07-25-2018

Rheem RAKA-024
Tech performed maintenance tune up on their Rheem A/C unit. Capacitor wasn't functioning as it should and unit needed an acid wash on the back side of the unit.
Waterford, WI
07-25-2018

RAKA-024
A/C tune up, checked out condenser coil, charges, filter, t-stat, all wiring, capacitor,compressor controls. Found unit is clogged, wires eaten (animal) and capacitor isn't working as it should, unit also low 1lb on freon. Replaced capacitor, 1lb freon, and replaced 2 wires. Unit is now working as designed.

Waterford, WI
07-25-2018

RAKA-024
Technician performed a A/C tune up on their Frigidaire unit. Cleaned and check all wiring, t-stat, temp, controls, compressor, contactor, capacitor, condenser coil. Unit is operating properly at this time.

Waterford, WI
07-25-2018

RAKA-024
Technician performed routine maintenance checking all components such as compressor, capacitor, t-stat, all wiring, contactor, condenser fan motor, filter. Unit is working properly at this time.

Waterford, WI
07-25-2018

Trane TTB024C100A
Tech did a routine maintenance and checked all components as t-stat, all wiring, compressor, contactor, capacitor, condenser coil and filter. Unit is working properly at this time.
Waterford, WI
07-25-2018

TTB024C100A
Technician was there for a routine A/C tune up. Checked and cleaned condenser coil, capacitor, contactor, checked all wiring and t-stat, filter and charges. Found h/o needed a new filter and they were low on R22 by 1 lb so added that. Unit is now working properly.

Waterford, WI
07-25-2018

Goodman CKL30*
Tech did a routine A/C check on their Goodman unit. Checked and or cleaned filter, t-stat, temps, compressor controls, all wiring, condenser. Unit is now working properly at this time.
Waterford, WI
07-25-2018

CKL30*
Tech conducted an A/C tune up on homeowner Frigidaire A/C unit. Cleaned and serviced condenser coil, charges, capacitor, contactor, compressor, controls, all wiring, t-state and filter. The unit is working properly at this time.

Waterford, WI
07-25-2018

CKL30*
Routine A/C tune up on homeowners Rheem unit. Cleaned/checked split system, condenser coil, capacitor, filter, t-stat, all wiring, contactor and compressor. The UV bulb was burnt out we ordered one and returned to install it. Unit is working as designed.

Waterford, WI
07-25-2018

Lennox 13ACC-024
A/C tune up, tech checked and or cleaned condenser coil, capacitor,compressor, controls, all wiring, filter and t-stat. Unit was in need of a 40/5 capacitor and because the coil was dirty tech did an acid wash. Unit running properly at this time.
Waterford, WI
07-25-2018

13ACC-024
Technician removed a Carrier A/C unit and installed a 3-ton Ducane 4AC13L36P-10A air conditioner and a EC1P36BL-1 cased evap coil. System and unit working properly at this time.

Waterford, WI
07-26-2018

13ACC-024
Technician went out on a no heat call on a Bryant furnace. He diagnosed that the collector box, hose and gasket weren't functioning as they should. Replaced all three parts and unit is operating properly at this time.

Waterford, WI
07-26-2018

13ACC-024
Technician went out on a air conditioning tune up on a Trane unit. Cleaned and serviced condenser coil, charges, capacitor, contactor, compressor, controls, all wiring, t-stat, and filter. Found filter needing to be replaced and unit was a little low on r410a. Tech replaced filter with Flex 2 filter and added 1 lb of r410a.

Waterford, WI
07-26-2018

13ACC-024
Routine tune up and technician checked/cleaned blower motor, condenser coil, capacitor, all wiring, board, filter, temps, t-stat. Unit operating properly at this time.

Waterford, WI
07-26-2018

13ACC-024
Technician went out for a a/c tune up on the Rheem unit. Cleaned and serviced all working components and found unit was 1 lb low on r410A refrigertant and it had been filled in 2017. Also condenser fan motor was leaking oil. Homeowner chose to replace the unit. We installed a 4AC13L36P-10A air conditioner and also a EU1P36BN-1 encased evap coil. Unit is up and running at this time.

Waterford, WI
07-26-2018

13ACC-024
Routine A/C tune up on their Frigidaire unit. 410a, filter and drains all good. Unit is 1 year old

Waterford, WI
07-26-2018

Trane TTR030C*
Technician went out on a no heat call and found Trane A/C unit low on freon and added 1 lb. Unit is now cooling well after adding refrigerant. Tech also tightened down outside service valves.
Waterford, WI
07-30-2018

TTR030C*
Technician went out on a no air conditioning call and found that the National Comfort unit had a plugged up condenser coil. Tech cleaned and unit is running properly.

Waterford, WI
07-31-2018

TTR030C*
Per the technician the compressor on this Lennox unit was drawing low amps 9.2 and actual is 16.3 causing the unit to freeze over

Waterford, WI
07-31-2018

Carrier 38TXA0303
Technician went out on a "no air conditioning" call and found the dual cap wasn't working as designed, replace dual cap 45/5. Ran Carrier unit and now cooling properly.
Waterford, WI
08-01-2018

38TXA0303
Homeowner requested a quote for a new hot water heater and a boiler, which we gave to her.

Waterford, WI
08-01-2018

Rheem 14AJM-30-A
Cooling tune up
Waterford, WI
08-03-2018

14AJM-30-A
INSTALL AC UNIT

Waterford, WI
08-03-2018

Rheem 13AJA36
COOLING TUNE UP. ACID WASHED CONDENSER AND CHANGED FILTER
WATERFORD, WI
08-03-2018

13AJA36
PS COOLING TUNE UP

WATERFORD, WI
08-03-2018

13AJA36
PS COOLING TUNE UP.

WATERFORD, WI
08-03-2018

13AJA36
PS COOLING TUNE UP. FOUND UNIT IS CLOGGED WITH DEBRIS

WATERFORD, WI
08-03-2018

13AJA36
PS COOL TUNE. FOUND DELAY TIMER AND CONTACTOR BAD FROM COMPRESSOR DRAWING HIGH AMPS

WATERFORD, WI
08-03-2018

Trane TTB024C100A
PS COOLING TUNE UP. FOUND LOW 1 LB R22. COMPRESSOR DRAWING HIGH AMPS
WATERFORD, WI
08-03-2018

TTB024C100A
REPLACED A/C CONDENSER & COIL

WATERFORD, WI
08-03-2018

TTB024C100A
REPLACED CIRCUIT BOARD AND T-STAT

Waterford, WI
08-03-2018

Lennox 13ACD-036
PS COOLING TUNE UP
WATERFORD, WI
08-03-2018

Lennox 13ACC-030
PS COOLING TUNE UP
WATERFORD, WI
08-03-2018

13ACC-030
INSTALLED T-STAT

Waterford, WI
08-06-2018

Ruud UAKA-030JAZ
FOUND CRACKED DRAIN PAN ON A COIL.
WATERFORD, WI
08-06-2018

UAKA-030JAZ

WATERFORD, WI
08-07-2018

UAKA-030JAZ
INSTALLED 2.5 TON DUCANE CONDENSER AND COIL

WATERFORD, WI
08-07-2018

UAKA-030JAZ
REPAIRED 2WIRE THAT WAS CHEWED BY CRITTERS

WATERFORD, WI
08-08-2018

Lennox 10ACB30
REPLACED CONTACTOR AND CAPACITOR
WATERFORD, WI
08-08-2018

Frigidaire FS4BD024K
INSTALLED DUAL CAP AND RESISTOR UNDER WARRANTY
WATERFORD, WI
08-08-2018