At Rosenthal Heating & Air Conditioning, we install and service all brands of central air conditioning and cooling systems in Racine, WI. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Racine, WI.

Let us help you decide how best to solve your air conditioning needs today.


Heil furnace no heat, the units board no longer functioning as it should. Replaced with a new White-Rogers ignition control board. Unit now working as designed.

Racine, WI
07-24-2018


Technician cleaned flame sensor and furnace.

Racine, WI
07-24-2018


On customers York 2-ton A/C unit technician found the capacitor wasn't working properly and replaced it. The freon and cooling ok now, no need to add freon at this time.

Racine, WI
07-24-2018


Technician cleaned and adjusted flame sensor on this Carrier furnace. Cycled 5 times and unit is working properly at this time.

Racine, WI
07-25-2018


Technician went on on a no heat call. Diagnosis on the Air-Flo furnace was the gas valve did stick for a second but opened up and unit was working as designed.

Racine, WI
07-25-2018


Technician went out on a no air conditioning call and added 1/2 lb r22, no dye kit. Tightened both serve valves on the Tempstar A/C unit.

Racine, WI
07-27-2018

starstarstarstarstar
5 Star Rating
Rheem RAKA-030
Tech went out and reset the air conditioning circuit breaker. Now it is cooling well.
Racine, WI
07-30-2018

RAKA-030
Technician was called out for a "no heat" and the ignitor wasn't working properly aliong with bypassed high limit switch.

Racine, WI
07-30-2018

RAKA-030
Technician found the air conditioning breaker was off so he reset it and Rheem unit is cooling properly.

Racine, WI
07-31-2018

Lennox HS29-018
Tech went out on "no air conditioning " call and found the Lennox unit had a malfunctioning dual cap and he replaced it. Now unit is cooling properly.
Racine, WI
07-31-2018

HS29-018
Per tech this ICP Acroaire unit has 3B partial shield caps the needed to be removed. Unit was also low on R22 which was added.

Racine, WI
07-31-2018

Rheem RAKA-024
When technician arrived for a no a/c call he found the Rheem unit was a little low on R22. Added 1/4 lb and unit was cooling much better, also tightened both outside service valves and condensor.
Racine, WI
08-01-2018

RAKA-024
On this Lennox unit the technician found the board needed to be replaced which he did and unit running properly.

Racine, WI
08-01-2018

RAKA-024
INSPECTION

RACINE, WI
08-03-2018

RAKA-024
CHANGED OUT INDUCER MOTOR AND COLLECTOR BOX

Racine, WI
08-03-2018

RAKA-024
FOUND FAN SIDE OF DUAL CAP LOW. REPLACED CAPACITOR

RACINE, WI
08-06-2018

RAKA-024
COOLING TUNE UP

RACINE, WI
08-06-2018

RAKA-024
COOLING TUNE UP

RACINE, WI
08-07-2018

RAKA-024

Racine, WI
08-07-2018

RAKA-024
TURNED FURNACE DIP SWITCHES TO MAXIMUM CFM FOR BETTER AIR FLOW

RACINE, WI
08-07-2018

RAKA-024
FOUND SMALL CONDENSATE LEAKS @ CORNERS OF PLENUM AND SILICONED THEM CLOSED. A/C OK COOLS WELL. CONDENSATION NEAR PLENUM IS NORMAL WITH A/C

RACINE, WI
08-08-2018

Armstrong HVAC SCU10A42
FOUND PLUGGED CONDENSER COIL CAUSING HIGH PRESSURES. CLEANED COIL AND ALSO REPLACED BURNED CONTACTOR. NOW COOLING WELL.
RACINE, WI
08-09-2018

Rheem RAKA-024
This Rheem Air conditioning unit wasn't cooling. Tech went out to find there were 2 ad 4 wire voltage @ circuit board, unit wasn't wired correctly. Corrected the issue and unit is now working as it should.
Racine, WI
08-16-2018

RAKA-024
This Heil Air conditioning unit wasn't cooling as it should. After our technician went out he needed to replace a malfunctioning dual cap and contactor unit was cooling and quiet.

Racine, WI
08-16-2018

RAKA-024
UNIT LOW 1 LB R22 ADDED AND COOLING GOOD

RACINE, WI
08-23-2018

RAKA-024
REPLACED 3.5 TON CONDENSER (PAYNE) AND EVAP COIL

RACINE, WI
08-30-2018

RAKA-024
REPLACED BLOWN 35/5 DUAL CAP

RACINE, WI
08-31-2018

RAKA-024
HEATING TUNE UP

RACINE, WI
09-24-2018